Solar Battery Size Calculator: How Many kWh for Backup Power

Work out how many kWh of home battery you need to keep chosen appliances running through an outage, and how many battery units that takes. Edit the appliance list, choose days of backup and see the capacity, unit count and peak load.

Solar Battery Size Calculator

Refrigerator (average draw)
Chest freezer
LED lights (several rooms)
Internet router and modem
Phone and laptop charging
TV
CPAP or medical device
Furnace blower (gas heat)
Well pump
Sump pump
Microwave
Central AC or heat pump (3-ton)

Most US outages last hours, not days, but storms can last longer.

More optionsFewer options

Only if your system is designed to recharge off-grid. Use 0 to be safe.

Check the spec sheet: many lithium batteries list 90–100% usable.

Energy you get back for each unit stored.

Common home units range from about 5 to 15 kWh.

From the spec sheet. Limits how much can run at once.

Your result

Battery capacity needed 6.7 kWh

Battery units
1
Backed-up use per day
5.7 kWh
Peak load if all run at once
1.6 kW

To run the loads you picked for the time you chose, plan on about 6.7 kWh of battery, or 1 unit(s) of the size entered. Your selected loads use 5.7 kWh a day.

Educational estimate only. Not financial, tax or legal advice.

Daily backup energy by appliance
Refrigerator (average draw): 3.6 kWh (63.2%)LED lights (several rooms): 0.6 kWh (10.5%)Internet router and modem: 0.7 kWh (12.6%)Phone and laptop charging: 0.1 kWh (1.4%)TV: 0.4 kWh (7%)Microwave: 0.3 kWh (5.3%)5.7 kWh
  • Refrigerator (average draw)
  • LED lights (several rooms)
  • Internet router and modem
  • Phone and laptop charging
  • TV
  • Microwave
View as table
AppliancekWh per day
Refrigerator (average draw)3.6 kWh
LED lights (several rooms)0.6 kWh
Internet router and modem0.7 kWh
Phone and laptop charging0.1 kWh
TV0.4 kWh
Microwave0.3 kWh

Your backup load list

ApplianceWattsHours/daykWh/day
Refrigerator (average draw)150243.6
LED lights (several rooms)10060.6
Internet router and modem30240.72
Phone and laptop charging2040.08
TV10040.4
Microwave1,2000.30.3
Total1,6005.7

Compare 1, 2 or 3 days of backup

ResultA 1 dayB 2 daysC 3 daysDifference (B − A)
Capacity needed6.7 kWh13.4 kWh20 kWh+6.7 kWh
Battery units1120

Results update as you type. Without JavaScript you see the worked example below.

How to use it

  1. Set the watts and hours per day for each appliance you want to keep running, and set hours to 0 for anything you can skip.
  2. Choose the days of backup you want to cover.
  3. Under advanced, enter solar recharge per day if your system can recharge during an outage, or leave it at 0.
  4. Enter the usable share, round-trip efficiency, unit capacity and continuous power from the battery spec sheet.
  5. Read the capacity needed, battery units and peak load, then compare 1, 2 and 3 days of backup.

A solar battery size calculator adds up the daily kWh of the appliances you want during an outage, multiplies by the days of backup, then allows for usable capacity and losses. With the defaults, essentials use 5.7 kWh a day and need about 6.7 kWh of battery, so one 13.5 kWh unit covers a one-day outage.

How to use the solar battery size calculator

  1. Appliance list. Each row has watts and hours per day. The defaults are a Refrigerator (average draw) at 150 W for 24 hours, LED lights (several rooms) 100 W for 6 hours, Internet router and modem 30 W for 24 hours, Phone and laptop charging 20 W for 4 hours, TV 100 W for 4 hours and Microwave 1,200 W for 15 minutes. Chest freezer, CPAP or medical device, Furnace blower (gas heat), Well pump, Sump pump and Central AC or heat pump (3-ton) start at 0 hours; set hours to include them.
  2. Days of backup. Default 1.
  3. Advanced fields. Solar recharge per day during outage (0), Usable share of battery capacity (90%), Round-trip efficiency (90%), Capacity of one battery unit (13.5 kWh) and Continuous power of one unit (5 kW).

You get the capacity needed, the number of battery units, backed-up use per day and peak load. A donut chart shows each appliance's share of daily energy, and a load-list schedule (watts, hours, kWh per day, with totals) can be downloaded as CSV. The scenario table reruns your list for 1, 2 and 3 days of backup.

How the calculation works

Daily kWh        = sum of (watts × hours) ÷ 1,000 for each appliance
Peak kW          = sum of watts of every appliance you included ÷ 1,000
Energy needed    = daily kWh + (daily kWh − solar recharge) × (days − 1)
Capacity needed  = energy needed ÷ usable share ÷ √(round-trip efficiency)
Units for energy = round up (capacity needed ÷ unit kWh)
Units for power  = round up (peak kW ÷ unit kW)
Battery units    = the larger of the two (at least 1)

Assumptions that match the code:

  • The first day comes entirely from storage; solar recharge only reduces later days.
  • Peak load is worst case: every included appliance running together, without motor starting surges.
  • Half the round-trip loss (the square root) is charged to discharging, since the battery starts full.
  • The 13.5 kWh unit default matches the median home battery installed with solar in 2025 (LBNL, 2026 (opens in a new tab)).

Worked example

Default inputs: the default appliance list, 1 day, no solar recharge, 90% usable, 90% round trip, 13.5 kWh and 5 kW per unit.

  • Daily use: refrigerator 3.6 + lights 0.6 + internet 0.72 + charging 0.08 + TV 0.4 + microwave 0.3 = 5.7 kWh.
  • Capacity needed: 5.7 ÷ 0.9 ÷ 0.949 = 6.7 kWh, so 1 battery unit.
  • Peak load if all run at once: 1.6 kW, well under one unit's 5 kW.

The default scenario table shows 6.7 kWh (1 unit) for one day, 13.4 kWh (1 unit) for two days and 20 kWh (2 units) for three.

Second example, a storm-season home: the default list plus a CPAP (60 W for 8 hours), a gas furnace blower (500 W for 8 hours) and a sump pump (800 W for 2 hours), with 2 days of backup.

  • Daily use: 11.8 kWh; peak load: 2.96 kW.
  • Capacity needed: 27.6 kWh, or 3 units of 13.5 kWh.
  • If the system can recharge about 8 kWh a day from solar during the outage, the need drops to 18.2 kWh, or 2 units.
Backup plan (example 2 loads)Capacity needed13.5 kWh units
1 day13.8 kWh2
2 days, no solar recharge27.6 kWh3
2 days, 8 kWh/day solar recharge18.2 kWh2
3 days, no solar recharge41.4 kWh4

Note how 13.8 kWh just misses one 13.5 kWh unit. Trimming a load, such as fewer TV hours, can save a whole unit.

What your result means

The result is a target for usable storage, not a shopping list. Check it against quotes: a proposal for one battery when your list needs 27 kWh, or three batteries when you need 7, deserves questions. To see how long a specific battery lasts at a given load, use the battery backup runtime calculator. Our home battery backup guide covers whole-home versus partial-home backup, and battery vs generator compares costs.

Rules that change the answer

  • Federal credit. The 25D credit covered home batteries of at least 3 kWh, but as of October 2026 it does not apply to installations completed after December 31, 2025 (IRS Form 5695 instructions (opens in a new tab)). Batteries owned by a leasing company follow separate §48E rules.
  • Safety codes. Home batteries should be listed to UL 9540 and installed under NFPA 855 (opens in a new tab) and local codes, which can limit where large batteries go.
  • Export rules. In California's net billing, a battery also earns bill savings by shifting solar to the evening; see are solar batteries worth it.
  • Storm exposure. Hurricane-prone areas may justify more days; see solar panels in Florida.

Common mistakes

  • Using nameplate watts for a refrigerator instead of its average draw.
  • Forgetting the furnace blower on gas heat or a well pump.
  • Ignoring peak power, so the battery has enough kWh but cannot start everything.
  • Counting on solar recharge from a system that shuts off in an outage.
  • Sizing for whole-home AC when a few essential circuits would do.

Limits of this calculator

This is an educational estimate. It uses average watts, ignores motor starting surges and battery aging, and assumes the battery is full when the outage starts. Real usable capacity, inverter limits and backup wiring vary by product and installer, so confirm sizing with a load calculation in a written proposal.

Frequently asked questions

What size battery do I need to back up my house?

It depends on what you keep running. With the default list (refrigerator, lights, internet, phone charging, TV and a little microwave use), you need about 6.7 kWh for one day, which one 13.5 kWh unit covers. Adding a CPAP, gas furnace blower and sump pump for two days raises it to about 27.6 kWh, or three units.

Can a home battery run central air conditioning?

Sometimes, but it takes a lot of capacity. Running a 3,500 W central AC or heat pump for 8 hours a day on top of the default loads uses about 33.7 kWh a day, which needs about 39.5 kWh of battery, or three 13.5 kWh units, for a single day. Motor starting surges may also need a soft starter or a larger inverter.

Why is the capacity needed bigger than my daily use?

Two adjustments. Most batteries cannot use 100 percent of their rated capacity, so the tool divides by the usable share, 90 percent by default. It also divides by the square root of round-trip efficiency, about 0.95 at 90 percent, to cover losses on the discharge side.

What does peak load mean and why does it matter?

Peak load is the total watts if everything you picked runs at once. Each battery unit can only deliver so much continuous power, 5 kW by default. If peak load exceeds what your units can deliver, the tool adds units even when energy alone would not require them.

Does solar recharge the battery during an outage?

Only if the system is designed for it. Many grid-tied systems shut down during an outage for safety unless the inverter and battery can form an island and keep the panels running. If yours can, enter a realistic daily recharge; the first day is always covered from storage alone. Use 0 if unsure.

How big is a typical home battery?

LBNL reports the median home battery installed with solar in 2025 was 13.5 kWh, which is the calculator's default unit size. About 37 percent of new home solar systems in 2025 included a battery, up from 25 percent in 2024.

How long do most power outages last?

Most are measured in hours, but hurricanes, ice storms and wildfire-prevention shutoffs can last days. Choose days of backup based on your area's history and whether anyone at home depends on powered medical equipment.

What safety standards should a home battery meet?

Look for a battery system listed to UL 9540, installed according to NFPA 855 and your local fire and building codes. Inverters that connect to the grid are typically listed to UL 1741. Your installer and permit inspection should confirm these.

Sources

Checked against these sources. Dates show when each was last reviewed.

  1. U.S. Distributed Solar and Storage: 2026 Data Update (opens in a new tab), Lawrence Berkeley National Laboratory (as ofOctober 2026)
  2. NFPA 855: Standard for the Installation of Stationary Energy Storage Systems (opens in a new tab), National Fire Protection Association (as ofOctober 2026)
  3. UL 9540 Energy Storage Systems and Equipment (opens in a new tab), UL Standards and Engagement (as ofOctober 2026)
  4. Homeowner's Guide to Going Solar (opens in a new tab), U.S. Department of Energy (as ofOctober 2026)
  5. Instructions for Form 5695 (opens in a new tab), Internal Revenue Service (as ofOctober 2026)
Last updated: How we build our calculators

Related guides

Menu